Please click HERE to go to our new website
Eurotron,IRtec,Portable,Infrared,Thermometers

Eurotron IRtec Portable
Infrared Thermometers


Products

  Flue Gas Analyzers
  Flue Gas Analyzer
  UniGas 2000
  UniGas 3000
  UniGas 4000
  Econoline Plus EN
  Greenline Mk II

  Infrared
  Thermometers
  Infrared Thermometers

  IRtec Miniray 100
  
IRtec P500+
  IRtec P800, P1000
  IRtec P1300
  IRtec P1600, P2000

  Multifunction
  Calibrators

  Multifunction Calibrators
  Palmtop Calibrator
  
High Accuracy Calibrator
  Two Channel Calibrator
  Very High Accuracy
  Calibrator


  Multi-Loop
  Controllers

  Multi-Loop Controllers

  Pressure
  Pressure Calibrators
  Pressure Transmitters
  Smart Pressure Transmitter

  Process
  Process Calibrators
  Process Multi-Meters
  Process Simulators

  PLC's
  PLC's

  Valves
  Valve Positioners


 





  Eurotron IRtec Portable Infrared Thermometers

IRtec P500+  Specifications

Model

IRtec P500
Range

from -30°C to +930°C

Wavelength

8-14 µm

Accuracy

±1% rdg  or ±1°C wichever is greater

Repeatability

±0.5% rdg or ±1°C wichever is greater

Stability

±0.01% f.s. for the band exceeding +18°C to +28°C

Accuracy analog OUT (1mV/°C/°F/K)

±1mV/°C/°F/K

Accuracy aux Tc K IN (-100 to 1370°C) ±(0.07%rdg+0.5°C)
Accuracy aux Tc S IN (0 to 1760°C) ±(0.07%rdg+2.5°C)

Optical System

The optical system is equipped with a main objective to focus the infrared energy into the infrared detector through a single lens, a filter and a field stop which defines the visual cone and therefore the target dimensions. As the detector is placed in the focal point of the measurement portion of the optical system no focusing operations are required. A secondary, but extremely important objective, is the correct pinpointing of the target as described below

Target Pinpointing

A correct aiming at the target is an important factor of a non-contact thermometer. The immediate evaluation of the smallest measurable target area is also a positive key factor in many applications. The following types of pinpointing are available :

  • A "V" groove on the up side of the instrument can be used stending the arm.
  • Single laser pointer to identify the center of the target area.
  • Circular spot laser pointer to define, at distance, the measurable target dimensions.
  • Twin laser pointers to define the diameter of the target area. Two versions are available with crossing or parallel twin lasers.
It is easy to operate with IRtec P thermometers using a laser pinpointing system. You simply aim at the target and read its temperature.

Thermocouple Input

To extend the operative capability the instrument is optionally equipped with an auxiliary input for thermocouple. This feature, when used with a calibrated thermocouple, can be used to obtain accurate temperature measurements eliminating the problems of emissivity and the interfering light. The thermocouple can be used to obtain an accurate temperature reading of the target material and then these data are used to determine the compensation value for the actual emissivity, including the interfering light, within a range from 0.10 to 1.00.

Analog Output

An analog output (1 mV/°C/°F) is optionally available to drive an external analog input device (eg. a potentiometric or hybrid recorder) for long term trend profiling and tests. In this case the instrument can be powered directly from mains using the external power supply module.


Logging Mode

The instrument can be equipped with an internal memory to store up to 500 input data. Two types of data acquisitions can be selected by the user.

  • Continuous acquisition: The operator can select the interval time between each acquisition and store progressively the input data in the Tag file or can manually, step by step, give the acquisition instruction
  •  Acquisition by dedicated tag: Standard Agencies and Quality Auditors require the collection, organization and availability of traceability documents. A supporting software is available to transfer a selection of plant inspections from a PC to the internal memory of the instrument in order to simplify field check and select the appropriate tag number. Dedicated input data are memory stored and downloaded into a PC to document the inspection activity. Data can be saved on disks, viewed and printed in a numeric or graphic mode.

Calculated Measurements

For the measurement of unstable input signals by a progressive averaging with a programmable average weight. In addition the operator can select average, minimum, maximum, Tmax -Tmin, differential.

EMC Conformity

The instrument case, made in shock-resistant injection moulded ABS + polycarbonate has an internal metal coating to fulfil the prevision of the directive 89/336/CEE Electromagnetic Compatibility. See Appendix A1 for the copy of EMC Declaration of Conformity.

Report of Calibration

Each IRtec portable IR thermometer is factory calibrated and certified against Eurotron Standards, that are periodically certified by an International recognized Laboratory, and shipped with a Report of Calibration stating the nominal and actual values and the deviation errors.

Logging Data Manager

LogMan software allows the IRtec users to set and prepare the infrared thermometers to acquire tha data organized by ‘Tag’. This software also allows to download data from Instrument on document ( table ) with date, time and value. You can view table, save table, print table, export table in excel-txt-html and obtain graph. You can also manage data coping, moving on other tables